Uncertainty of Results in Clinical Diagnostic Laboratory Examination

Abstract


The article examines the critical role of measurement uncertainty assessment in ensuring the reliability of the results of clinical diagnostic laboratories. A two-component measurement uncertainty model is analyzed which includes a component related to the traceability of results to the highest standards provided by the manufacturer of in vitro diagnostic systems and a component characterizing the reproducibility of measurements in a specific laboratory evaluated on the basis of in-laboratory quality control. The methodology for calculating the total measurement uncertainty is presented and its mandatory indication along with the analysis result in the format «Value ± measurement uncertainty (%)» which determines the range of possible values of the true value. The clinical importance of taking measurement uncertainty into account when interpreting laboratory data is emphasized. Using the example of the threshold value of anti-Muller hormone for deciding on the possibility of in vitro fertilization it is demonstrated how ignoring the uncertainty interval can lead to an erroneous refusal of treatment. The key challenges of the widespread introduction of measurement uncertainty into practice are noted: the need to maintain clinical diagnostic laboratories in a state of statistical manageability ensuring the reliability and completeness of data from in vitro diagnostic manufacturers modifying laboratory forms and most importantly training clinicians in the principles of interpreting results taking into account uncertainty. It is concluded that the integration of measurement uncertainty into routine laboratory reporting and clinical decision-making is a necessary condition for improving diagnostic quality minimizing errors and ensuring patient safety.

About the authors

V. V. Maslennikov

Research Institute for Healthcare Organization and Medical Management of Moscow Healthcare Department 115088 Moscow Russia

References

  1. Wadhwa N. Bhat K. Kalsi M. Sadhu T. Evaluation of measurement uncertainty in clinical chemistry and its comparison with analytical performance specifications // Cureus. 2025. Vol. 17 N 2. P. e79043. doi: 10.7759/cureus.79043
  2. Panteghini M. Redesigning the surveillance of in vitro diagnostic medical devices and of medical laboratory performance by quality control in the traceability era // Clin. Chem. Lab. Med. 2022. Vol. 61 N 5. P. 759—768. doi: 10.1515/cclm-2022-1257
  3. Plebani M. Padoan A. Sciacovelli L. Measurement uncertainty: light in the shadows // Clin. Chem. Lab. Med. 2020. Vol. 58 N 9. P. 1381—1383. doi: 10.1515/cclm-2020-0134
  4. Magnusson B. Ossowicki H. Rienitz O. Theodorsson E. Routine internal- and external-quality control data in clinical laboratories for estimating measurement and diagnostic uncertainty using GUM principles // Scand. J. Clin. Lab. Invest. 2012. Vol. 72 N 3. P. 212—220. doi: 10.3109/00365513.2011.649015
  5. Plebani M. Padoan A. Sciacovelli L. Measurement uncertainty: light in the shadows // Clin. Chem. Lab. Med. 2020. Vol. 58 N 9. P. 1381—1383. doi: 10.1515/cclm-2020-0134
  6. Coskun A. Bias in laboratory medicine: the dark side of the moon // Ann. Lab. Med. 2024. Vol. 44 N 1. P. 6—20. doi: 10.3343/alm.2024.44.1.6
  7. Panteghini M. Not all biases are created equal: how to deal with bias on laboratory measurements // Clin. Chem. Lab. Med. 2024. Vol. 63 N 5. P. 916—922. doi: 10.1515/cclm-2024-1208
  8. Soll R. F. Ovelman C. McGuire W. The future of Cochrane Neonatal // Early Hum. Dev. 2020. Vol. 150. P. 105191. doi: 10.1016/j.earlhumdev.2020.105191
  9. Milinković N. Jovičić S. Ignjatović S. Measurement uncertainty as a universal concept: can it be universally applicable in routine laboratory practice? // Crit. Rev. Clin. Lab. Sci. 2021. Vol. 58 N 2. P. 101—112. doi: 10.1080/10408363.2020.1784838
  10. Braga F. Panteghini M. The utility of measurement uncertainty in medical laboratories // Clin. Chem. Lab. Med. 2020. Vol. 58 N 9. P. 1407—1413. doi: 10.1515/cclm-2019-1336
  11. Panteghini M. Braga F. Camara J. E. et al. Optimizing available tools for achieving result standardization: value added by Joint Committee on Traceability in Laboratory Medicine // Clin. Chem. 2021. Vol. 67 N 12. P. 1590—1605. doi: 10.1093/clinchem/hvab178
  12. Panteghini M. Camara J. E. Delatour V. et al. Feasibility of metrological traceability implementation using the Joint Committee on Traceability in Laboratory Medicine database entries including the fulfillment of «Fit-for-Purpose» maximum allowable measurement uncertainty // Clin. Chem. 2024. Vol. 70 N 11. P. 1321—1333. doi: 10.1093/clinchem/hvae131

Statistics

Views

Abstract - 0

PDF (Russian) - 0

Cited-By


PlumX

Dimensions


Copyright (c) 1970 АО "Шико"

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

Mailing Address

Address: 105064, Vorontsovo Pole, 12, Moscow

Email: ttcheglova@gmail.com

Phone: +7 903 671-67-12

Principal Contact

Tatyana Sheglova
Head of the editorial office
FSSBI «N.A. Semashko National Research Institute of Public Health»

105064, Vorontsovo Pole st., 12, Moscow


Phone: +7 903 671-67-12
Email: redactor@journal-nriph.ru

This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies