<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE root>
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="research-article" dtd-version="1.1d1" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher">Problems of Social Hygiene, Public Health and History of Medicine</journal-id><journal-title-group><journal-title>Problems of Social Hygiene, Public Health and History of Medicine</journal-title></journal-title-group><issn publication-format="print">0869-866X</issn><issn publication-format="electronic">2412-2106</issn><publisher><publisher-name>Joint-Stock Company Chicot</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">2349</article-id><article-id pub-id-type="doi">10.32687/0869-866X-2025-33-s2-977-981</article-id><article-categories><subj-group subj-group-type="heading"><subject>Научная статья</subject></subj-group></article-categories><title-group><article-title>Uncertainty of Results in Clinical Diagnostic Laboratory Examination</article-title></title-group><contrib-group><contrib contrib-type="author"><name name-style="western"><surname>Maslennikov</surname><given-names>V. V.</given-names></name><email></email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff id="aff-1">Research Institute for Healthcare Organization and Medical Management of Moscow Healthcare Department 115088 Moscow Russia</aff><pub-date date-type="epub" iso-8601-date="2025-10-24" publication-format="electronic"><day>24</day><month>10</month><year>2025</year></pub-date><volume>33</volume><fpage>977</fpage><lpage>981</lpage><history><pub-date date-type="received" iso-8601-date="2025-10-27"><day>27</day><month>10</month><year>2025</year></pub-date></history><permissions><copyright-statement>Copyright © 1970,</copyright-statement><copyright-year>1970</copyright-year></permissions><abstract>The article examines the critical role of measurement uncertainty assessment in ensuring the reliability of the results of clinical diagnostic laboratories. A two-component measurement uncertainty model is analyzed which includes a component related to the traceability of results to the highest standards provided by the manufacturer of in vitro diagnostic systems and a component characterizing the reproducibility of measurements in a specific laboratory evaluated on the basis of in-laboratory quality control. The methodology for calculating the total measurement uncertainty is presented and its mandatory indication along with the analysis result in the format «Value ± measurement uncertainty (%)» which determines the range of possible values of the true value. The clinical importance of taking measurement uncertainty into account when interpreting laboratory data is emphasized. Using the example of the threshold value of anti-Muller hormone for deciding on the possibility of in vitro fertilization it is demonstrated how ignoring the uncertainty interval can lead to an erroneous refusal of treatment. The key challenges of the widespread introduction of measurement uncertainty into practice are noted: the need to maintain clinical diagnostic laboratories in a state of statistical manageability ensuring the reliability and completeness of data from in vitro diagnostic manufacturers modifying laboratory forms and most importantly training clinicians in the principles of interpreting results taking into account uncertainty. It is concluded that the integration of measurement uncertainty into routine laboratory reporting and clinical decision-making is a necessary condition for improving diagnostic quality minimizing errors and ensuring patient safety.</abstract><kwd-group xml:lang="en"><kwd>measurement uncertainty</kwd><kwd>clinical diagnostic laboratories</kwd><kwd>metrological traceability</kwd><kwd>presentation of results</kwd><kwd>diagnostic errors</kwd><kwd>in-laboratory quality control</kwd></kwd-group><kwd-group xml:lang="ru"><kwd>неопределённость измерения</kwd><kwd>клинико-диагностические лаборатории</kwd><kwd>метрологическая прослеживаемость</kwd><kwd>форма представления результатов</kwd><kwd>диагностические ошибки</kwd><kwd>внутрилабораторный контроль качества</kwd></kwd-group></article-meta></front><body></body><back><ref-list><ref id="B1"><label>1.</label><mixed-citation>Wadhwa N. Bhat K. Kalsi M. Sadhu T. Evaluation of measurement uncertainty in clinical chemistry and its comparison with analytical performance specifications // Cureus. 2025. Vol. 17 N 2. P. e79043. DOI: 10.7759/cureus.79043</mixed-citation></ref><ref id="B2"><label>2.</label><mixed-citation>Panteghini M. Redesigning the surveillance of in vitro diagnostic medical devices and of medical laboratory performance by quality control in the traceability era // Clin. Chem. Lab. Med. 2022. Vol. 61 N 5. P. 759—768. DOI: 10.1515/cclm-2022-1257</mixed-citation></ref><ref id="B3"><label>3.</label><mixed-citation>Plebani M. Padoan A. Sciacovelli L. Measurement uncertainty: light in the shadows // Clin. Chem. Lab. Med. 2020. Vol. 58 N 9. P. 1381—1383. DOI: 10.1515/cclm-2020-0134</mixed-citation></ref><ref id="B4"><label>4.</label><mixed-citation>Magnusson B. Ossowicki H. Rienitz O. Theodorsson E. Routine internal- and external-quality control data in clinical laboratories for estimating measurement and diagnostic uncertainty using GUM principles // Scand. J. Clin. Lab. Invest. 2012. Vol. 72 N 3. P. 212—220. DOI:10.3109/00365513.2011.649015</mixed-citation></ref><ref id="B5"><label>5.</label><mixed-citation>Plebani M. Padoan A. Sciacovelli L. Measurement uncertainty: light in the shadows // Clin. Chem. Lab. Med. 2020. Vol. 58 N 9. P. 1381—1383. DOI: 10.1515/cclm-2020-0134</mixed-citation></ref><ref id="B6"><label>6.</label><mixed-citation>Coskun A. Bias in laboratory medicine: the dark side of the moon // Ann. Lab. Med. 2024. Vol. 44 N 1. P. 6—20. DOI:10.3343/alm.2024.44.1.6</mixed-citation></ref><ref id="B7"><label>7.</label><mixed-citation>Panteghini M. Not all biases are created equal: how to deal with bias on laboratory measurements // Clin. Chem. Lab. Med. 2024. Vol. 63 N 5. P. 916—922. DOI: 10.1515/cclm-2024-1208</mixed-citation></ref><ref id="B8"><label>8.</label><mixed-citation>Soll R. F. Ovelman C. McGuire W. The future of Cochrane Neonatal // Early Hum. Dev. 2020. Vol. 150. P. 105191. DOI: 10.1016/j.earlhumdev.2020.105191</mixed-citation></ref><ref id="B9"><label>9.</label><mixed-citation>Milinković N. Jovičić S. Ignjatović S. Measurement uncertainty as a universal concept: can it be universally applicable in routine laboratory practice? // Crit. Rev. Clin. Lab. Sci. 2021. Vol. 58 N 2. P. 101—112. DOI: 10.1080/10408363.2020.1784838</mixed-citation></ref><ref id="B10"><label>10.</label><mixed-citation>Braga F. Panteghini M. The utility of measurement uncertainty in medical laboratories // Clin. Chem. Lab. Med. 2020. Vol. 58 N 9. P. 1407—1413. DOI: 10.1515/cclm-2019-1336</mixed-citation></ref><ref id="B11"><label>11.</label><mixed-citation>Panteghini M. Braga F. Camara J. E. et al. Optimizing available tools for achieving result standardization: value added by Joint Committee on Traceability in Laboratory Medicine // Clin. Chem. 2021. Vol. 67 N 12. P. 1590—1605. DOI:10.1093/clinchem/hvab178</mixed-citation></ref><ref id="B12"><label>12.</label><mixed-citation>Panteghini M. Camara J. E. Delatour V. et al. Feasibility of metrological traceability implementation using the Joint Committee on Traceability in Laboratory Medicine database entries including the fulfillment of «Fit-for-Purpose» maximum allowable measurement uncertainty // Clin. Chem. 2024. Vol. 70 N 11. P. 1321—1333. DOI: 10.1093/clinchem/hvae131</mixed-citation></ref></ref-list></back></article>
